Building on over 30 years of ground-breaking research, Optical Scientific, Inc. (OSI) has developed a world-wide reputation for accuracy and rugged reliability. OSI's product line of advanced optical sensors, present weather sensors, and AWOS systems are recognized as leaders in the global market.
Our family of optical sensors and systems are found at work in critical applications everywhere in the world - on land and sea.
Building on over 30 years of ground-breaking research, Optical Scientific, Inc. (OSI) has developed a world-wide reputation for accuracy and rugged reliability. OSI's product line of advanced optical sensors, present weather sensors, and AWOS systems are recognized as leaders in the global market.
Our family of optical sensors and systems are found at work in critical applications everywhere in the world - on land and sea.
AWOS Systems
AWOS AV
Fully Automated Aviation Weather System
• FAA-Certified Barometric Pressure and Visibility
• FAA-Approved Wind Speed/Direction
- Temperature Sensor
- Humidity Sensor
- Ceilometer
• FCC-Licensed VHF Data Radio
• Best Value • High Performance • Reasonable Cost
AWOS Systems
MAWOS
Modular Automated Weather Observation System
• Easily-Customizable AWOS System
• Precipitation • Visibility • Wind Speed/Direction
• Barometric Pressure • Relative Humidity
• Ceilometer • Pyranometer • Hail & Ice
• Tide/Wave Height & More • Multi-lingual Voice Reporting • Serial Port • USB • Internet • VHF • Cell Phone
AWOS Systems • HazMet 100
HazMet 100
Portable Weather Station
• Rapid Response to Environmental Hazard
• Deploys in Minutes
• ALOHA Dispersion Modeling Software
• AC, Solar, or Battery Power
• Long-Range Spread-Spectrum Radio
• Operates Stand-Alone or Networked
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
• OFS 2000F for Flare Gas
• OFS 2000 for Air Assisted Flare
• OFS 2000R for Steam Assisted Flare
Meets or exceeds EPA, SCAQMD and EU requirements
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
Non-Intrusive
No direct contact with flow media. Immune to the effects of temperature, gas density, moisture content, particulate count, or pressure. If OFS 2000 can detect turbulence-induced fluctuations with even a fraction of the light, it can accurately measure the flow velocity. It is, in this sense, a “pure” measurement.
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
No Calibration Required
Using scintillation as a basis of measurement means the all-digital / DSP-based OFS 2000 systems require no calibration – ever. Our patented process is supported with over 20 million hours of observation data, and certified by NIST (National Institute of Standards.) Automatic calibration check along with continuous self-test diagnostics are built-in for user security.
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
Full-Path Averaging
OFS 2000 provides a dynamic velocity measurement of the passage of gas or air through a light beam averaged directly across the entire volume. Scintillation through the entire path is detected, analyzed, calculated, and reported - a much more representative measurement than single point or slanted path.
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
Measurement Reporting By
• 4-20mA Current Loop
• RS 232/485
• ModBus RTU
• Network/Fiber Optic Connectivity
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
Measurement Not Affected By
• Distance
• Pressure
• Temperature
• Gas Density
• Moisture
• Opacity
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
Measurement Not Dependent On
• Differential pressure
• Design DP
• Beta ratio
• Temperature
• Gas composition
• Humidity
• Speed of sound
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
Flexible Installation
OFS can install in tight spaces with minimum space requirements of 2 upstream / 1 downstream diameters. No re-piping needed. Installation is to standard ANSI pattern 4” pipe flange. OFS can be installed on live process pipes using hot tap procedure and gate valves for isolation.
No shutdown or interruption required.
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
Flexible Communication
All systems are equipped with analog current loop / digital data outputs, and can be configured with Serial port, Limited Distance Modem, and Fiber Optic Interface for any type of WAN or LAN.
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
No Moving Parts
OFS 2000 is essentially maintenance-free, save for window cleaning. OFS internal monitoring alerts the user if window cleaning is required. (Typically only semi-annually (if then) on the dirtiest stack and duct applications.)
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
Assures Compliance
All OFS 2000 sensors meet or exceed requirements set by the Environmental Protection Agency, and California’s South Coast Air Quality Management District.
AlEPA Method 14
EPA MACT RSR 40 CFR 63.670
EPA 40 CFR part 60 & 75
EPA 40 CFR part 60 sub part J & Ja
SCAQMD rule 1118
AWOS Systems • HazMet 100 • OFS 2000
Flight Operations
Emergency Response
Control & Compliance
AWOS Systems
AWOS AV
AWOS AV
Fully Automated Aviation Weather System
• FAA-Certified Barometric Pressure and Visibility
• FAA-Approved Wind Speed/Direction
Temperature Sensor
Humidity Sensor
Ceilometer
• FCC-Licensed VHF Data Radio
• Best Value • High Performance • Reasonable Cost
AWOS Systems
MAWOS
MAWOS
Modular Automated Weather Observation System
• Easily-Customizable AWOS System
• Precipitation • Visibility • Wind Speed/Direction
• Barometric Pressure • Relative Humidity
• Ceilometer • Pyranometer • Hail & Ice
• Tide/Wave Height & More • Multi-lingual Voice Reporting
• Serial Port • USB • Internet • VHF • Cell Phone
AWOS Systems • HazMet 100
HazMet 100
HazMet 100
Portable Weather Station
• Rapid Response to Environmental Hazard
• Deploys in Minutes
• ALOHA Dispersion Modeling Software
• AC, Solar, or Battery Power
• Long-Range Spread-Spectrum Radio
• Operates Stand-Alone or Networked
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
• OFS 2000F for Flare Gas
• OFS 2000 for Air Assisted Flare
• OFS 2000R for Steam Assisted Flare
Meets or exceeds EPA, SCAQMD and EU requirements
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
Non-Intrusive
No direct contact with flow media. Immune to the effects of temperature, gas density, moisture content, particulate count, or pressure. If OFS 2000 can detect turbulence-induced fluctuations with even a fraction of the light, it can accurately measure the flow velocity. It is, in this sense, a “pure” measurement.
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
No Calibration Required
Using scintillation as a basis of measurement means the all-digital / DSP-based OFS 2000 systems require no calibration – ever. Our patented process is supported with over 20 million hours of observation data, and certified by NIST (National Institute of Standards.) Automatic calibration check along with continuous self-test diagnostics are built-in for user security.
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
Full-Path Averaging
OFS 2000 provides a dynamic velocity measurement of the passage of gas or air through a light beam averaged directly across the entire volume. Scintillation through the entire path is detected, analyzed, calculated, and reported - a much more representative measurement than single point or slanted path.
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
Measurement Reporting By
• 4-20mA Current Loop
• RS 232/485
• ModBus RTU
• Network/Fiber Optic Connectivity
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
Measurement Not Affected By
• Distance
• Pressure
• Temperature
• Gas Density
• Moisture
• Opacity
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
Measurement Not Dependent On
• Differential pressure
• Design DP
• Beta ratio
• Temperature
• Gas composition
• Humidity
• Speed of sound
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
Flexible Installation
OFS can install in tight spaces with minimum space requirements of 2 upstream / 1 downstream diameters. No re-piping needed. Installation is to standard ANSI pattern 4” pipe flange. OFS can be installed on live process pipes using hot tap procedure and gate valves for isolation.
No shutdown or interruption required.
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
Flexible Communication
All systems are equipped with analog current loop / digital data outputs, and can be configured with Serial port, Limited Distance Modem, and Fiber Optic Interface for any type of WAN or LAN.
AWOS Systems • HazMet 100 • OFS 2000
OFS 2000 Optical Flow Sensor
Air/ Gas/ Steam Velocity with Mass/ Volumetric Flow
No Moving Parts
OFS 2000 is essentially maintenance-free, save for window cleaning. OFS internal monitoring alerts the user if window cleaning is required. (Typically only semi-annually (if then) on the dirtiest stack and duct applications.)
AWOS Systems • HazMet 100 • OFS 2000
AWOS Systems • HazMet 100 • OFS 2000
Flight Operations
Emergency Response
Control & Compliance
Optical Scientific, Inc.
2 Metropolitan Court
Suite 6
Gaithersburg, MD 20878 USA
Tel: +01 301 963 3630
Fax: +01 301 948 4674
website: opticalscientific.com
E-mail: infoft@opticalscientific.com